| Operating Mode |
synchronous |
| Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL
|
SIL3 ready |
SIL3 |
| Hoist Capacity in kg on Chain |
2000 kg – single reeved,
4000 kg – double reeved |
| Max. Travel in m |
up to 65 m* |
| Max. Speed in m/s |
4 m/min, (2 m/min in double reeved operation) |
| Variable Speed |
yes, depending on control |
yes |
| Duty Cycle |
up to 55% / 50 Hz |
| Noise Level |
approx. 56 dBA |
| No. of Drops* |
1 |
| Load Bearing Line |
chain 13 x 36 mm (not included) |
| Load Carrying Device |
eyelet (included) |
| Type of Material – Chassis |
steel |
| Chassis Colour |
black |
| Type of Material – Cover |
steel |
| Cover Colour |
black |
| Installation Method |
hanging |
| Safety System |
dynamic self-locking gear |
| Gear Box Type |
TDA-10 i=100 |
| Gear Box Design |
worm |
| Gearbox Safety |
safety catch |
| Motor Type |
asynchronous motor, 2 pol |
| Motor Performance in kW |
3 kW motor |
| Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
Encoder System
|
2 x absolute encoder (SSI Interface) |
| Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
| Type of Hoist Control |
not supplied |
ASM GENESIS SIL 3 |
| Position of Hoist Control |
not supplied |
external, ASM power pack |
| Control Equipment |
none |
GENESIS SIL3 power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (4 kW), including 1,2 m multi-pin connection cable (Harting) |
| Cable Interface |
ASM standard terminal interface (Harting)** (cable led out 1,2 m) |
ASM standard connector interface (Harting) between hoist and power pack |
| Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
| Power Cable |
not supplied |
1,5 m
CEE 5 PIN-16 A |
| Dimensions (without external PowerPack) in mm, H x W x D |
|
| Weight (without external Power Pack, without Ropes) in kg |
120 kg |
| Including |
documentation |
| eyelet |