Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL
|
SIL 3 ready |
SIL3 |
Hoist Capacity in kg |
250 |
Breaking Strength of Steel Band |
29 kN |
Max. Travel in m |
24 |
Max. Speed in m/s |
1,2 |
Variable Speed |
yes, depending on control |
yes |
Duty Cycle |
up to 90% / 50 Hz |
Noise Level |
approx. 48 dBA |
No. of Drops* |
1 |
Load Bearing Line |
steel band, 45 x 0,4 mm |
Load Carrying Device |
eyelet |
Type of Material – Chassis |
combination of aluminium and steel |
Chassis Colour |
black |
Type of Material – Cover |
aluminium |
Cover Colour |
black |
Installation Method |
hanging or self-climbing |
Safety System |
2 independent theatre brakes |
Gear Box Type |
TS-10 i=19,67 |
Gear Box Design |
worm |
Gearbox Safety |
2 x nominal torque/400h lifetime + safety catch |
Motor Type |
servo (Hiperface, PMSM) |
Motor Performance in kW |
3,8 kW motor |
Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
Encoder System |
2 x absolute encoder (SSI Interface) |
Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
Slack Band Detection |
yes, short circuit sensor |
Type of Hoist Control |
not supplied |
ASM GENESIS SIL 3 |
Position of Hoist Control |
not supplied |
external, ASM power pack |
Control Equipment |
none |
GENESIS SIL3 servo power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter, including 2 m multi-pin connection cable (Harting) |
Cable Interface |
ASM standard connector interface (Harting) |
Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
Power Cable |
not supplied |
1,5 m
CEE 5 PIN-16 A |
Dimensions (without external PowerPack) in mm, H x W x D |
635 mm mm x 612 mm x 494 mm |
Weight (without external Power Pack, without Ropes) in kg |
85 |
Including |
|
GENESIS SIL3 servo Power Pack |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
documentation |