| Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL
|
SIL 3 ready |
SIL3 |
| Hoist Capacity in kg |
250 |
| Breaking Strength of Steel Band |
29 kN |
| Max. Travel in m |
24 |
| Max. Speed in m/s |
1,2 |
| Variable Speed |
yes, depending on control |
yes |
| Duty Cycle |
up to 90% / 50 Hz |
| Noise Level |
approx. 48 dBA |
| No. of Drops* |
1 |
| Load Bearing Line |
steel band, 45 x 0,4 mm |
| Load Carrying Device |
eyelet |
| Type of Material – Chassis |
combination of aluminium and steel |
| Chassis Colour |
black |
| Type of Material – Cover |
aluminium |
| Cover Colour |
black |
| Installation Method |
hanging or self-climbing |
| Safety System |
2 independent theatre brakes |
| Gear Box Type |
TS-10 i=19,67 |
| Gear Box Design |
worm |
| Gearbox Safety |
2 x nominal torque/400h lifetime + safety catch |
| Motor Type |
servo (Hiperface, PMSM) |
| Motor Performance in kW |
3,8 kW motor |
| Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
| Encoder System |
2 x absolute encoder (SSI Interface) |
| Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
| Slack Band Detection |
yes, short circuit sensor |
| Type of Hoist Control |
not supplied |
ASM GENESIS SIL 3 |
| Position of Hoist Control |
not supplied |
external, ASM power pack |
| Control Equipment |
none |
GENESIS SIL3 servo power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter, including 2 m multi-pin connection cable (Harting) |
| Cable Interface |
ASM standard connector interface (Harting) |
| Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
| Power Cable |
not supplied |
1,5 m
CEE 5 PIN-16 A |
| Dimensions (without external PowerPack) in mm, H x W x D |
635 mm x 612 mm x 494 mm |
| Weight (without external Power Pack, without Ropes) in kg |
85 |
| Including |
|
GENESIS SIL3 servo Power Pack |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
| documentation |