Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL
|
depending on control |
SIL2 |
SIL3 ready |
SIL3 |
SIL3 ready |
SIL3 |
SIL3 ready |
SIL3 |
Hoist Capacity in kg on Chain |
up to 1000 |
Max. Travel in m |
up to 40* |
Max. Speed in m/min |
4 |
18 |
Variable Speed |
yes, depending on control |
no |
yes, depending on control |
yes |
yes, depening on control |
yes |
yes, depening on control |
yes |
Duty Cycle |
up to 50% / 50 Hz |
up to 65% / 50 Hz |
up to 90% / 50 Hz |
Noise Level |
approx. 55 dBA |
No. of Drops |
1 |
Load Bearing Line |
chain 10 x 28 (not included) |
Load Carrying Device |
eyelet – included (hook – on request) |
Type of Material – Chassis |
steel |
Chassis Colour |
black |
Type of Material – Cover |
rubber |
Cover Colour |
black |
Safety System |
dynamic irreversible gearbox |
2 independent theatre brakes (Mayr) |
Gear Box Type |
TS-10 i=99 |
TS-10 i=41 |
Gear Box Design |
worm |
Gearbox Safety |
safety catch |
2 x nominal torque/400 h lifetime and safety catch |
Motor Type |
noise reduced asynchronous motor, 2 pol |
servo (Hiperface, PMSM) |
Motor Performance in kW |
1,5 kW motor |
3 kW |
3,8 kW |
Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
Encoder System |
none |
2 x absolute encoder (SSI Interface) |
2 x absolute encoders (SSI Interface) | 1 x incremental encoders (TTL interface, 1 for closed loop) |
2 x absolute encoder (SSI Interface) |
Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
Underload Detection |
yes, depending on control |
yes |
yes, depending on control |
yes |
yes, depending on control |
yes |
yes, depending on control |
yes |
Type of Hoist Control |
not supplied |
ASM 24 V DC control |
not supplied |
ASM GENESIS SIL3 |
not supplied |
ASM GENESIS SIL3 |
not supplied |
ASM GENESIS SIL3 |
Position of Hoist Control |
not supplied |
external, ASM power pack |
not supplied |
external, ASM power pack |
not supplied |
external, ASM power pack |
not supplied |
external, ASM power pack |
Control Equipment |
none |
3 phase reversing contactor control with E-stop management, control voltage 24 V DC |
none |
GENESIS SIL3 power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (2,2 kW), including 1,2 m multi-pin connection cable (Harting) |
none |
GENESIS SIL3 power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (7,5 kW), including 1,2 m multi-pin connection cable (Harting) |
none |
GENESIS SIL3 servo power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter, including 1,2 m multi-pin connection cable (Harting) |
Cable Interface |
ASM standard terminal interface (Harting)**(cable led out 1,2 m) |
control connector XLR-RJ45 | CEE 5 PIN-16 A (cable led out 1,2 m) |
ASM standard terminal interface (Harting)**(cable led out 1,2 m) |
ASM standard connector interface (Harting) between hoist and power pack |
ASM standard connector interface (Harting) |
ASM standard connector interface (Harting) between hoist and power pack |
ASM standard connector interface (Harting) |
ASM standard connector interface (Harting) between hoist and power pack |
Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
Power Cable |
not supplied |
1,2 m
CEE 5 PIN-16 A |
not supplied |
1,5 m
CEE 5 PIN-16 A |
not supplied |
1,5 m
CEE 5 PIN-16 A |
not supplied |
1,5 m
CEE 5 PIN-16 A |
Dimensions (without external PowerPack) in mm, H x W x D |
288 mm x 292 mm x 497 mm (without chain bag) |
Weight (without external Power Pack, without Chain) in kg |
54 kg |
55 kg |
58 kg |
68 kg |
67 kg |
Including |
documentation |
eyelet or hook |