Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL
|
SIL 3 ready |
SIL3 |
SIL3 ready |
SIL3 |
Hoist Capacity in kg on Ropes |
up to 1200 |
Breaking Strength of Recommanded Rope |
23 kN |
40 kN |
Max. Travel in m |
22 |
16 |
Max. Speed in m/s |
0,13 |
Variable Speed |
yes, depending on control |
yes |
yes, depending on control |
yes |
Duty Cycle |
up to 51% / 50 Hz |
Noise Level |
approx. 48 dBA |
No. of Drops* |
8 |
6 |
Load Bearing Line |
rope, 6 mm (not included) |
rope, 8 mm (not included) |
Load Carrying Device |
load bar (not included) |
Type of Material – Chassis |
steel |
Chassis Colour |
black |
Type of Material – Cover |
steel |
Cover Colour |
black |
Safety System |
2 independent theatre breakes (Mayr) |
Gear Box Type |
TDA4,5 i=41 |
Gear Box Design |
worm |
Gearbox Safety |
2 x nominal torque/400 h lifetime and safety catch |
Motor Type |
noise reduced asynchronous motor, 4 pol |
Motor Performance in kW |
5,5 kW motor |
Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
Encoder System |
2x absolute encoder (SSI interface) + 2x incremental encoder (TTL interface, 1 for closed loop) |
Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
Slack Rope Detection |
yes, short circuit sensor |
Type of Hoist Control |
not supplied |
ASM GENESIS SIL 3 |
not supplied |
ASM GENESIS SIL 3 |
Position of Hoist Control |
not supplied |
external, ASM power pack |
not supplied |
external, ASM power pack |
Control Equipment |
none |
GENESIS SIL3 power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (7,5 kW), including 2 m multi-pin connection cable (Harting) |
none |
GENESIS SIL3 power pack (16 kHz) with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (7,5 kW), including 2 m multi-pin connection cable (Harting) |
Cable Interface |
ASM standard connector interface (Harting) ** |
ASM standard connector interface (Harting) between hoist and power pack |
ASM standard connector interface (Harting) ** |
ASM standard connector interface (Harting) between hoist and power pack |
Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
Power Cable |
not supplied |
1,5 m
CEE 5 PIN-16 A |
not supplied |
1,5 m
CEE 5 PIN-16 A |
Dimensions (without external PowerPack) in mm, H x W x D |
1795 mm x 252 mmx 652 mm |
Weight (without external Power Pack, without Ropes) in kg |
~ 235 kg |
Including |
basic mounting brackets (L) and fixing equipment |
quick links for rope attachment |
|
GENESIS SIL3 power pack |
|
GENESIS SIL3 power pack |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
|
documentation |