GRIDPOINT

Jump to Dimension
GP TM 108

1-8-SIL3

GP TM 108

1-8-GSG-SIL3

GP TM 115

1-8-SIL3

GP TM 108

1-8-GSG-SIL3

Operating Mode synchronous (ready) synchronous synchronous (ready) synchronous
Regulation DGUV V 17 (before BGV C1), DIN EN 17206
SIL Level SIL 3 ready SIL3 SIL 3 ready SIL3
Hoist Capacity in kg on Ropes up to 350* up to 350* up to 500* up to 500*
Variable Speed 2,4 m/s 3 m/s
Breaking Strength of Recommanded Rope 66 kN
Max. Travel in m 40
Noise Level 1,8 m/sec   ≈ 49 Hz   ,    2,4 m / sec  ≈  65
Hz
Variable Speed yes, depending on control yes yes, depending on control yes
Duty Cylce 80% / 50 Hz
Noise Level approx. 49 dBA
No. of Drops* 1
Load Bearing Line rope, 8 mm included and mounted
Load Carrying Device Swivel eyelet with death load included
Type of Material – Chassis aluminium
Chassis Colour black
Type of Material – Cover steel / aluminium
Cover Colour black
Safety System 2 independent theatre brakes
Installation Method on wheels
Gearbox Type ASM TM TWE
Gear Box Design TM redundant
Gearbox Safety 2 x nominal torque / 400 h lifetime + safety catch
Motor Type 2x asynchronous motor 4 kW 2x asynchronous motor 5,5 kW
Motor Performance in kW 2 x 4 kW motor = 8 kW 2 x 5,5 kW motor = 15 kW
Limit Switch 4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits)
Encoder System 2 x absolute encoders (SSI interface) for SIL3, 2 x incremental encoders (TTL interface), 1x for closed loop
Load Sensing (total load) load cell | 4-20 mA | SIL3
Type of Hoist Control not supplied ASM GENESIS SIL 3 not supplied ASM GENESIS SIL 3
Position of Hoist Control not supplied external, ASM power pack not supplied external, ASM power pack
Control Equipment none GENESIS SIL3 PowerPack 11 kW with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (16 kHz), including 2 m multi-pin connection cable (Harting) none GENESIS SIL3 PowerPack 11 kW with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (16 kHz), including 2 m multi-pin connection cable (Harting)
Cable Interface ASM standard connector interface (Harting) incl. wiring scheme ASM standard connector interface (Harting) between hoist and power pack ASM standard connector interface (Harting) incl. wiring scheme ASM standard connector interface (Harting) between hoist and power pack
Main / Motor Supply U1 / V1 / W1 / PE (400 V 50/60 Hz) 3 PH / N / PE (400 V 50/60 Hz) via external Power Pack U1 / V1 / W1 / PE (400 V 50/60 Hz) 3 PH / N / PE (400 V 50/60 Hz) via external Power Pack
Power Cable not supplied 1,8 m | CEE 5 PIN-16 A not supplied 1,8 m | CEE 5 PIN-16 A
Dimensions (without external PowerPack) in mm, H x W x D 788 x 774 x 1730 mm in position for operation 818 x 774 x 1730 mm in position for operation
788 x 774 x 1258 mm in position for storage 818x 774 x 1258 mm in position for storage
Weight (without external Power Pack, without Ropes) in kg approx. 280 kg approx. 290 kg
Including
trolley & drop arm
documentation