Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
SIL Level |
SIL 3 ready |
SIL3 |
Hoist Capacity in kg on Ropes |
250 |
Breaking Strength of Recommanded Steel Band |
29 kN |
Max. Travel in m |
20 |
Max. Speed in m/s |
1,2 |
Variable Speed |
yes, depending on control |
yes |
Duty Cycle |
up to 76% / 50 Hz |
Noise Level |
up to approx. 48 dBA |
No. of Drops* |
1 |
Load Bearing Line |
steel band, 30 x 0,6 mm |
Load Carrying Device |
eyelet |
Type of Material – Chassis |
steel |
Chassis Colour |
black |
Type of Material – Cover |
aluminum |
Cover Colour |
black |
Installation Method |
hanging |
Safety System |
2 independent theatre brakes (Mayer) |
Gear Box Type |
TDA 4.5 i=19,67 |
Gear Box Design |
worm |
Gearbox Safety |
2 x nominal torque/400 h lifetime and safety catch |
Motor Type |
noise reduced asynchronous, 2 pol |
Motor Performance in kW |
3 kW motor |
Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
Encoder System |
2 x absolute encoders (SSI interface) for SIL3| 1 x incremental encoders (TTL interface, 1 for closed loop) |
Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
Slack Band Detection |
yes, short circut sensor |
Type of Hoist Control |
not supplied |
ASM GENESIS SIL 3 |
Position of Hoist Control |
not supplied |
external, ASM power pack |
Control Equipment |
none |
GENESIS SIL3 PowerPack 3 kW with ASM TWINCORE SIL3 axis card, E-stop management, brake management and frequency inverter (16 kHz) |
Cable Interface |
ASM standard connector interface (Harting) |
Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
Power Cable |
not supplied |
1,8 m
CEE 5 PIN-16 A |
Dimensions (without external PowerPack) in mm, H x W x D |
497 mm x 459 mm 990 mm |
Weight (without external Power Pack, without Ropes) in kg |
128 |
Including |
|
GENESIS SIL3 servo Power Pack |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
documentation |