| Operating Mode |
synchronous (ready) |
synchronous |
synchronous (ready) |
synchronous |
| Regulation |
DGUV V 17 (before BGV C1), EN 17206 |
| SIL |
SIL3 ready |
SIL3 |
SIL3 ready |
SIL3 |
| Hoist Capacity in kg on Ropes |
650 |
| Breaking Strength of Recommanded Rope |
18 kN |
| Max. Travel in m |
11,5 |
| Max. Speed in m/s |
0,2 |
0,8 |
| Variable Speed |
yes, depending on control |
yes |
yes, depending on control |
yes |
| Duty Cycle |
up to 53% / 50 Hz |
up to 65% / 50 Hz |
| Noise Level |
approx. 49 dBA |
| No. of Drops* |
6 |
| Load Bearing Line |
rope, 5 mm (not included) |
| Load Carrying Device |
load bar (not included) |
| Type of Material – Chassis |
steel |
| Chassis Colour |
black |
| Type of Material – Cover |
steel |
| Cover Colour |
black |
| Safety System |
dynamic irreversible gearbox |
2 independent theatre brakes (Mayr) |
| Gear Box Type |
TDA4,5 i=99 |
TDA4,5 i=15,33 |
| Gear Box Design |
worm |
| Gearbox Safety |
safety catch |
2 x nominal torque/400 h lifetime and safety catch |
| Motor Type |
noise reduced asynchronous motor, 2 pol |
noise reduced asynchronous motor, 4 pol |
| Motor Performance in kW |
4 kW |
5,5 kW |
| Limit Switch |
4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits) |
| Encoder System |
2 x absolute encoder (SSI Interface) |
2 x absolute encoders (SSI interface) for SIL3 | 2 x incremental encoders (TTL interface, 1 for closed loop) |
| Load Sensing (total load) |
load cell | 4-20 mA | SIL3 |
| Slack Rope Detection |
yes, short circuit sensor |
| Type of Hoist Control |
not supplied |
ASM GENESIS SIL3 |
not supplied |
ASM GENESIS SIL3 |
| Position of Hoist Control |
not supplied |
external, ASM power pack |
not supplied |
external, ASM power pack |
| Control Equipment |
none |
GENESIS SIL3 power pack 5,5 kW with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (16 kHz) |
none |
GENESIS SIL3 power pack 7,5 kW with ASM TWINCORE SIL3 axis card, E-stop management, brake management and frequency inverter (16 kHz) |
| Cable Interface |
ASM standard connector interface (Harting) |
ASM standard connector interface (Harting) between hoist and power pack |
ASM standard connector interface (Harting) |
ASM standard connector interface (Harting) between hoist and power pack |
| Main / Motor Supply |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
U1 / V1 / W1 / PE (400 V 50/60 Hz) |
3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack |
| Power Cable |
not supplied |
1,5 m CEE 5 PIN-16 A |
not supplied |
1,5 m CEE 5 PIN-16 A |
| Dimensions (without external PowerPack) in mm, H x W x D |
1460 mm x 195 mm x 447 mm |
1507 mm x 198 mm x 447 mm |
| Weight (without external Power Pack, without Ropes) in kg |
~ 145 kg |
| Including |
basic mounting brackets (L) and fixing equipment |
| quick links for rope attachment |
|
GENESIS SIL 3 Power Pack 5,5 kW |
|
GENESIS SIL 3 Power Pack 7,5 kW |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
|
1,5 m power cable with CEE 16 A, 5 pin plug |
| documentation |