TECHNICAL OVERVIEW HCWA JR 400

Jump to Technical Drawing
HCWA JR 400 650-6-5-0,2- SIL3* HCWA JR 400 650-6-5-0,2- GSG-SIL3* HCWA JR 400 650-6-5-0,8- SIL3* HCWA JR 400 650-6-5-0,8- GSG-SIL3*
Operating Mode synchronous (ready) synchronous synchronous (ready) synchronous
Regulation DGUV V 17 (before BGV C1), EN 17206
SIL SIL3 ready SIL3 SIL3 ready SIL3
Hoist Capacity in kg on Ropes 650
Breaking Strength of Recommanded Rope 18 kN
Max. Travel in m 11,5
Max. Speed in m/s 0,2 0,8
Variable Speed yes, depending on control yes yes, depending on control yes
Duty Cycle up to 53% / 50 Hz up to 65% / 50 Hz
Noise Level approx. 49 dBA
No. of Drops* 6
Load Bearing Line rope, 5 mm (not included)
Load Carrying Device load bar (not included)
Type of Material – Chassis steel
Chassis Colour black
Type of Material – Cover steel
Cover Colour black
Safety System dynamic irreversible gearbox 2 independent theatre brakes (Mayr)
Gear Box Type TDA4,5 i=99 TDA4,5 i=15,33
Gear Box Design worm
Gearbox Safety safety catch 2 x nominal torque/400 h lifetime and safety catch
Motor Type noise reduced asynchronous motor, 2 pol noise reduced asynchronous motor, 4 pol
Motor Performance in kW 4 kW 5,5 kW
Limit Switch 4 track (Stromag) DGUV V17 (2 x operational limits + 2 x absolute limits)
Encoder System 2 x absolute encoder (SSI Interface) 2 x absolute encoders (SSI interface) for SIL3 | 2 x incremental encoders (TTL interface, 1 for closed loop)
Load Sensing (total load) load cell | 4-20 mA | SIL3
Slack Rope Detection yes, short circuit sensor
Type of Hoist Control not supplied ASM GENESIS SIL3 not supplied ASM GENESIS SIL3
Position of Hoist Control not supplied external, ASM power pack not supplied external, ASM power pack
Control Equipment none GENESIS SIL3 power pack 5,5 kW with ASM TWINCORE SIL3 axis card, E-stop management and frequency inverter (16 kHz) none GENESIS SIL3 power pack 7,5 kW with ASM TWINCORE SIL3 axis card, E-stop management, brake management and frequency inverter (16 kHz)
Cable Interface ASM standard connector interface (Harting) ASM standard connector interface (Harting) between hoist and power pack ASM standard connector interface (Harting) ASM standard connector interface (Harting) between hoist and power pack
Main / Motor Supply U1 / V1 / W1 / PE (400 V 50/60 Hz) 3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack U1 / V1 / W1 / PE (400 V 50/60 Hz) 3 PH / N / PE (400 V 50/60 Hz) via external ASM power pack
Power Cable not supplied 1,5 m CEE 5 PIN-16 A not supplied 1,5 m CEE 5 PIN-16 A
Dimensions (without external PowerPack) in mm, H x W x D 1460 mm x 195 mm x 447 mm 1507 mm x 198 mm x 447 mm
Weight (without external Power Pack, without Ropes) in kg ~ 145 kg
Including basic mounting brackets (L) and fixing equipment
quick links for rope attachment
GENESIS SIL 3 Power Pack 5,5 kW GENESIS SIL 3 Power Pack 7,5 kW
1,5 m power cable with CEE 16 A, 5 pin plug 1,5 m power cable with CEE 16 A, 5 pin plug
documentation

OPTIONS HCWA Junior

  • Basement designed for individual situation on site*
    • Basement*
    • Fixed Basement*
    • Basement with extra diverting pulley*
    • Tilting Basement*
  • Ropes
    • more ropes*
    • different rope sizes*
    • (…)*

*on request

DIMENSION HCWA JR 400

Jump to Technical Data
HCWA JR 400 D x H II 3
HCWA JR 400 W
HCWA JR 400 650-6-5-0,2- SIL3* HCWA JR 400 650-6-5-0,2- GSG-SIL3* HCWA JR 400 650-6-5-0,8- SIL3* HCWA JR 400 650-6-5-0,8- GSG-SIL3*
Dimensions (without external PowerPack) in mm, H x W x D 1460 mm x 195 mm x 447 mm 1507 mm x 198 mm x 447 mm
Weight (without external Power Pack, without Ropes) in kg ~ 145 kg